Package | de.medizininformatikinitiative.kerndatensatz.icu |
Type | StructureDefinition |
Id | Id |
FHIR Version | R4 |
Source | https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.icu@2025.0.0-ballot.1&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-beatmung |
Url | https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-beatmung |
Version | 2025.0.0 |
Status | active |
Name | SD_MII_ICU_Parameter_Von_Beatmung |
Title | SD MII ICU Parameter von Beatmung |
Experimental | False |
Type | Observation |
Kind | resource |
Note: links and images are rebased to the (stated) source
{
"resourceType" : "StructureDefinition",
"id" : "sd-mii-icu-vent-parameter-von-beatmung",
"text" : {
"status" : "empty",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">No human-readable text provided in this case.</div>"
},
"url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-beatmung",
"version" : "2025.0.0",
"name" : "SD_MII_ICU_Parameter_Von_Beatmung",
"title" : "SD MII ICU Parameter von Beatmung",
"status" : "active",
"contact" : [
{
"name" : "Müller, Christoph",
"telecom" : [
{
"system" : "email",
"value" : "christmueller@ukaachen.de"
}
]
}
],
"fhirVersion" : "4.0.1",
"mapping" : [
{
"identity" : "workflow",
"uri" : "http://hl7.org/fhir/workflow",
"name" : "Workflow Pattern"
},
{
"identity" : "sct-concept",
"uri" : "http://snomed.info/conceptdomain",
"name" : "SNOMED CT Concept Domain Binding"
},
{
"identity" : "v2",
"uri" : "http://hl7.org/v2",
"name" : "HL7 v2 Mapping"
},
{
"identity" : "rim",
"uri" : "http://hl7.org/v3",
"name" : "RIM Mapping"
},
{
"identity" : "w5",
"uri" : "http://hl7.org/fhir/fivews",
"name" : "FiveWs Pattern Mapping"
},
{
"identity" : "sct-attr",
"uri" : "http://snomed.org/attributebinding",
"name" : "SNOMED CT Attribute Binding"
}
],
"kind" : "resource",
"abstract" : false,
"type" : "Observation",
"baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Observation",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "Observation",
"path" : "Observation",
"constraint" : [
{
"key" : "obs-10",
"severity" : "error",
"human" : "Either subject XOR encounter exists",
"expression" : "$this.encounter.exists() xor $this.subject.exists()",
"source" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-beatmung"
},
{
"key" : "vs-de-2",
"severity" : "error",
"human" : "If there is no component or hasMember element then either a value[x] or a data absent reason must be present",
"expression" : "(component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())",
"source" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-beatmung"
}
]
},
{
"id" : "Observation.identifier",
"path" : "Observation.identifier",
"mustSupport" : true
},
{
"id" : "Observation.partOf",
"path" : "Observation.partOf",
"short" : "Observation belongs to a specific extracorporeal procedure.",
"definition" : "Dasjenige extrakorporale Verfahren, im Rahmen dessen der vorliegende Parameter (die Daten dieser Observation-Ressource) erhoben wurden.",
"min" : 1,
"max" : "1",
"type" : [
{
"code" : "Reference",
"profile" : [
"https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference"
],
"targetProfile" : [
"http://hl7.org/fhir/StructureDefinition/Procedure"
]
}
],
"mustSupport" : true
},
{
"id" : "Observation.status",
"path" : "Observation.status",
"mustSupport" : true
},
{
"id" : "Observation.category",
"path" : "Observation.category",
"slicing" : {
"discriminator" : [
{
"type" : "pattern",
"path" : "$this"
}
],
"rules" : "open"
},
"min" : 1,
"max" : "1",
"mustSupport" : true,
"binding" : {
"strength" : "required",
"valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Category-Procedure-Beatmung-SNOMED"
}
},
{
"id" : "Observation.category.coding",
"path" : "Observation.category.coding",
"mustSupport" : true
},
{
"id" : "Observation.category.coding.system",
"path" : "Observation.category.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.category.coding.code",
"path" : "Observation.category.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code",
"path" : "Observation.code",
"mustSupport" : true
},
{
"id" : "Observation.code.coding",
"path" : "Observation.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "pattern",
"path" : "$this"
}
],
"ordered" : false,
"rules" : "open"
},
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code.coding:sct",
"path" : "Observation.code.coding",
"sliceName" : "sct",
"patternCoding" : {
"system" : "http://snomed.info/sct"
},
"mustSupport" : true,
"binding" : {
"strength" : "required",
"valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-Beatmung-SNOMED"
}
},
{
"id" : "Observation.code.coding:sct.system",
"path" : "Observation.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code.coding:sct.code",
"path" : "Observation.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code.coding:sct.display",
"path" : "Observation.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.code.coding:loinc",
"path" : "Observation.code.coding",
"sliceName" : "loinc",
"patternCoding" : {
"system" : "http://loinc.org"
},
"mustSupport" : true,
"binding" : {
"strength" : "required",
"valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-Beatmung-LOINC"
}
},
{
"id" : "Observation.code.coding:loinc.system",
"path" : "Observation.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code.coding:loinc.code",
"path" : "Observation.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code.coding:loinc.display",
"path" : "Observation.code.coding.display",
"mustSupport" : true
},
{
"id" : "Observation.code.coding:IEEE-11073",
"path" : "Observation.code.coding",
"sliceName" : "IEEE-11073",
"patternCoding" : {
"system" : "urn:iso:std:iso:11073:10101"
},
"mustSupport" : true,
"binding" : {
"strength" : "required",
"valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-Beatmung-ISO11073"
}
},
{
"id" : "Observation.code.coding:IEEE-11073.system",
"path" : "Observation.code.coding.system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.code.coding:IEEE-11073.code",
"path" : "Observation.code.coding.code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.subject",
"path" : "Observation.subject",
"min" : 1,
"type" : [
{
"code" : "Reference",
"profile" : [
"https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference"
],
"targetProfile" : [
"http://hl7.org/fhir/StructureDefinition/Patient",
"http://hl7.org/fhir/StructureDefinition/Device"
]
}
],
"mustSupport" : true
},
{
"id" : "Observation.encounter",
"path" : "Observation.encounter",
"type" : [
{
"code" : "Reference",
"profile" : [
"https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference"
]
}
],
"mustSupport" : true
},
{
"id" : "Observation.effective[x]",
"path" : "Observation.effective[x]",
"type" : [
{
"code" : "dateTime"
},
{
"code" : "Period"
}
],
"mustSupport" : true
},
{
"id" : "Observation.issued",
"path" : "Observation.issued",
"mustSupport" : true
},
{
"id" : "Observation.performer",
"path" : "Observation.performer",
"type" : [
{
"code" : "Reference",
"targetProfile" : [
"http://hl7.org/fhir/StructureDefinition/Practitioner",
"http://hl7.org/fhir/StructureDefinition/PractitionerRole",
"http://hl7.org/fhir/StructureDefinition/Organization",
"http://hl7.org/fhir/StructureDefinition/CareTeam"
]
}
]
},
{
"id" : "Observation.value[x]",
"path" : "Observation.value[x]",
"min" : 1,
"type" : [
{
"code" : "Quantity"
}
],
"patternQuantity" : {
"system" : "http://unitsofmeasure.org"
},
"mustSupport" : true
},
{
"id" : "Observation.value[x].value",
"path" : "Observation.value[x].value",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.value[x].unit",
"path" : "Observation.value[x].unit",
"mustSupport" : true
},
{
"id" : "Observation.value[x].system",
"path" : "Observation.value[x].system",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.value[x].code",
"path" : "Observation.value[x].code",
"min" : 1,
"mustSupport" : true
},
{
"id" : "Observation.dataAbsentReason",
"path" : "Observation.dataAbsentReason",
"mustSupport" : true
},
{
"id" : "Observation.bodySite",
"path" : "Observation.bodySite",
"binding" : {
"strength" : "extensible",
"valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/BodySite-Observation-Beatmung"
}
},
{
"id" : "Observation.device",
"path" : "Observation.device",
"type" : [
{
"code" : "Reference",
"profile" : [
"https://www.medizininformatik-initiative.de/fhir/core/StructureDefinition/MII-Reference"
],
"targetProfile" : [
"https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/devicemetric-eingestellte-gemessene-parameter-beatmung"
]
}
],
"mustSupport" : true
}
]
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.